Freescale Semiconductor /MK60DZ10 /FTM2 /MODE

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as MODE

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)FTMEN 0 (INIT)INIT 0 (0)WPDIS 0 (0)PWMSYNC 0 (0)CAPTEST 0 (00)FAULTM 0 (0)FAULTIE

WPDIS=0, FAULTM=00, FTMEN=0, PWMSYNC=0, CAPTEST=0, FAULTIE=0

Description

Features Mode Selection

Fields

FTMEN

FTM Enable

0 (0): Only the TPM-compatible registers (first set of registers) can be used without any restriction. Do not use the FTM-specific registers.

1 (1): All registers including the FTM-specific registers (second set of registers) are available for use with no restrictions.

INIT

Initialize the Channels Output

WPDIS

Write Protection Disable

0 (0): Write protection is enabled.

1 (1): Write protection is disabled.

PWMSYNC

PWM Synchronization Mode

0 (0): No restrictions. Software and hardware triggers can be used by MOD, CnV, OUTMASK, and FTM counter synchronization.

1 (1): Software trigger can only be used by MOD and CnV synchronization, and hardware triggers can only be used by OUTMASK and FTM counter synchronization.

CAPTEST

Capture Test Mode Enable

0 (0): Capture test mode is disabled.

1 (1): Capture test mode is enabled.

FAULTM

Fault Control Mode

0 (00): Fault control is disabled for all channels.

1 (01): Fault control is enabled for even channels only (channels 0, 2, 4, and 6), and the selected mode is the manual fault clearing.

2 (10): Fault control is enabled for all channels, and the selected mode is the manual fault clearing.

3 (11): Fault control is enabled for all channels, and the selected mode is the automatic fault clearing.

FAULTIE

Fault Interrupt Enable

0 (0): Fault control interrupt is disabled.

1 (1): Fault control interrupt is enabled.

Links

() ()